Andrew Heliax cable data
ANDREW |
7/8 HJ5-50 |
1” 5/8 HJ7-50 |
3” HJ8-50 |
|
Average power in |
@ 88 MHz |
6.84 |
15.4 |
39.7 |
@ 100 MHz |
6.40 |
14.4 |
37.0 |
|
@ 108MHz |
6.13 |
13.8 |
35.4 |
|
Max safe power in |
@ 88 MHz |
4.6 |
10.3 |
26.5 |
@ 100 MHz |
4.3 |
9.6 |
24.7 |
|
@ 108MHz |
4.1 |
9.2 |
23.6 |
|
Loss dB 100 feet |
@ 88 MHz |
0.347 |
0.194 |
0.131 |
@ 100 MHz |
0.370 |
0.207 |
0.140 |
|
@ 108MHz |
0.386 |
0.215 |
0.147 |
|
Connectors gas pass |
75AR |
87R |
*&ARF |
|
Connectors gas block |
75AG |
87G |
78AGF |
|
Inline bullet |
34389A |
34660 |
ACX350-20 |
|
Hangers part number |
42396A-5 |
42396A-2 |
31766A-11 |
|
Max spacing (Ft.) |
3’ |
3’ |
5’ |
|
Hoisting grip (Every |
19256B |
243112A |
26985A |
|
Grounding kit (every |
204989-2 |
204989-4 |
204989-5 |
|
Max. bending radius |
10” |
20” |
30” |
|
Andrew |